5.1The Infinity Bow™ at the Centre of a System

The Infinity Bow™ is an eclectic tool, created for postural training and for developing the exteroceptive and interoceptive sensory analysers (see section 10.2.1). To increase its effectiveness, specific accessories have been developed: each one brings attention to a precise part of the body or to a specific macro-action of the sequence, and trains it through visual, tactile, acoustic or kinaesthetic feedback. For each accessory this chapter explains what it is for, how it is made, how it is fitted, where it is used in the sequence and what safety precautions it requires.

In teaching terms the accessories are temporary scaffolding: they are introduced one at a time, used until the sensation has become the archer’s own, and then gradually removed (chapter 8).

AccessoryBody partType of feedbackMacro-actionsShooting style
AeroAxis™Elbow and scapula of the string armVisual (Aero-Line) and tactile (cord)7, 8, 9 and 13All
Infinity FormLine™Bow shoulder and bow armKinaesthetic (downward resistance)5All
G.A.S.™Bow handVisual (cross and bubble)3, 6 and 15All
Clicker Simulator™Expansion chainAcoustic and tactile (click)11Olympic recurve
I-LoopDraw and holding against the wallTactile (end stop)11Compound

5.2AeroAxis™ — String-Elbow Alignment and Air Lines

What it is for. It gives feedback on three aspects of the string arm’s work: the height of the drawing elbow (frontal plane), scapular opening (transverse plane, push/pull position) and the quality of the follow-through.

The AeroAxis™. In the background, the Air Lines with the string elbow high, in line and low.
Fig. AX.1 — The AeroAxis™. In the background, the Air Lines with the string elbow high, in line and low.

How it is made. A rigid triaxial device that wraps the medial and lateral epicondyles of the humerus and the olecranon of the ulna. Unlike flexible strap elbow braces, it transfers forces directly to the bony prominences of the elbow. The green cord (Aero-Line) materialises the Air Lines.

There are six components:

  • Bow-Clip Interface: a shaped mount that fits on the Infinity Bow™; the Tip-Lock Seat ensures quick, precise insertion, and two ambidextrous holes let you attach the Aero-Line on the side of the dominant eye.
  • Triaxial Plates: rigid modules that wrap the medial and lateral epicondyles of the humerus and spread the draw load without compressing the soft tissue of the forearm.
  • Position Adjuster: a sliding module mounted on the red load cord; it sits on the olecranon of the ulna and anchors the line of force at the centre of the joint.
  • Tension Block: an adjuster built into the green strap elastic between the two plates, which adapts the circumference of the AeroAxis™ to the archer’s arm.
  • Aero-Line guide cord: a high-visibility green cord that starts from the Position Adjuster and gives visual and tactile feedback on the Air Lines.
  • Vector Loop and quick-release Carabiner: the ends of the Aero-Line, which let you attach it to the Infinity Bow™ or to your own bow.
The components: a) Bow-Clip Interface; b) Triaxial Plates; c) Position Adjuster on the red load cord; d) Tension Block on the green strap el
Fig. AX.2 — The components: a) Bow-Clip Interface; b) Triaxial Plates; c) Position Adjuster on the red load cord; d) Tension Block on the green strap elastic; e) Aero-Line guide cord; f) Vector Loop and quick-release Carabiner.

Fitting. With the Infinity Bow™ it attaches to the Tip-Lock Seat via the Bow-Clip. With a real bow it hooks onto the thumb or the riser, at center-shot height. Complete fitting and the nine operating phases are described in the AeroAxis™ Technical Manual, available on archive.org.

There are six fitting phases:

Phase 1 — Insert the Bow-Clip. Fit the Bow-Clip Interface above the grip of the Infinity Bow™, matching the Tip (the component that holds the string with its two screws) with the clip’s Tip-Lock Seat. The rigid fit keeps the draw point fixed and parallel to the riser.

Phase 1: a) the clip slides onto the Tip; b) the clip in place, parallel to the riser; c) the clip fitted, with the hand on the grip.
Fig. AX.3 — Phase 1: a) the clip slides onto the Tip; b) the clip in place, parallel to the riser; c) the clip fitted, with the hand on the grip.

Phase 2 — Put on the AeroAxis™. Orient it with the green elastic of the Tension Block facing up and the red cord of the Position Adjuster facing the grip. Slide the string arm under the green elastic, palm facing up, and move the device up over the elbow.

Phase 3 — Position it on the elbow. Rest one Triaxial Plate on the medial epicondyle (the inner prominence of the elbow) and the other on the lateral epicondyle (the outer prominence). Slide the Position Adjuster along the red cord to the olecranon (the rear prominence).

Phases 2 and 3: a) orienting the device; b) the string arm goes under the green elastic, palm up; c) the Triaxial Plates on the epicondyles;
Fig. AX.4 — Phases 2 and 3: a) orienting the device; b) the string arm goes under the green elastic, palm up; c) the Triaxial Plates on the epicondyles; d) the Position Adjuster slides to the olecranon.

Phase 4 — Adjust the Tension Block. Slide it along its channels to tighten or loosen the strap until the fit is stable but comfortable.

Phase 5 — Attach the Aero-Line to the Infinity Bow™. Pass the quick-release Carabiner between the two front projections that hold the string and clip it to the Bow-Clip hole matching the dominant eye: right hole for a right dominant eye, left hole for the left.

Phases 4 and 5: a) and b) the Tension Block tightens or loosens the strap; c) the Carabiner passes between the front projections of the Infi
Fig. AX.5 — Phases 4 and 5: a) and b) the Tension Block tightens or loosens the strap; c) the Carabiner passes between the front projections of the Infinity Bow™; d) the Carabiner clipped to the Bow-Clip hole.

Phase 6 — Attach the Aero-Line to your own bow. On bows without a rest, slip the Vector Loop over the thumb of the bow hand, down to the base of the joint. On bows with a Berger button, hook the Loop onto its outer body. On a compound, secure the Loop on the outer mechanical part of the rest, or fix the Aero-Line to the riser at center-shot height with the Carabiner.

Phase 6: a) Vector Loop on the thumb; b) Loop on the outer body of the Berger button; c) Loop on the mechanical part of the compound rest; d
Fig. AX.6 — Phase 6: a) Vector Loop on the thumb; b) Loop on the outer body of the Berger button; c) Loop on the mechanical part of the compound rest; d) Aero-Line fixed to the riser at center-shot height.

How to read it. Under the Instructor’s supervision, the archer reaches the facial contact points and performs the scapular anchor. The AeroAxis™ is read on two planes:

Frontal plane (vertical Air Lines). From the front, the height of the drawing elbow is observed. Elbow high: the lower trapezius and rhomboid are not engaged and the shoulder is overloaded. Elbow in line: the elbow is on the extension of the arrow axis and bow arm, and the force is discharged onto the lower angle of the scapula. Elbow low: the back structure collapses and the biceps contracts too much. The draw point acting directly on the olecranon guides the elbow towards the in-line position and favours a fluid release.

Frontal plane, relative to the red line of the shooting axis: a) elbow high; b) elbow in line; c) elbow low.
Fig. AX.7 — Frontal plane, relative to the red line of the shooting axis: a) elbow high; b) elbow in line; c) elbow low.

Transverse plane (horizontal Air Lines). If the archer does not correctly rotate the scapula towards the spine, the Aero-Line does not align with the shoulder line and the geometry of the Wedge position does not form. The feedback is also tactile: with shoulders open and aligned, the Aero-Line rests softly on the knuckles of the string hand; with shoulders closed or a collapsing elbow, it stays detached.

Transverse plane, view from above: a) insufficient scapular rotation, the Aero-Line does not align with the shoulders; b) shoulders closed,
Fig. AX.8 — Transverse plane, view from above: a) insufficient scapular rotation, the Aero-Line does not align with the shoulders; b) shoulders closed, the Aero-Line stays off the knuckles; c) correct execution: the geometry of the Wedge position, with the Aero-Line resting on the knuckles.

In the sequence. Draw (7): the Aero-Line shows whether the elbow is high, in line or low. Contact and anchor (8 and 9): the Aero-Line aligns with the shoulders only with correct scapular rotation, and the cord brushes the knuckles and the base of the neck. Follow-through (13): the cord always touches the same point. Exercises 7.1, 9.1, 9.2 and 13.1. The two self-check exercises in the AeroAxis™ Technical Manual correspond to Exercises 9.2 (Aero-Line contact on the knuckles, eyes closed) and 13.1 (contact at the base of the neck during follow-through).

Self-check during expansion (Exercise 9.2). The learner draws to the facial contact point. The Instructor asks them to close their eyes and say whether they feel the Aero-Line touching the knuckles of the string hand, naming the knuckle where they feel it. If the Aero-Line does not touch, the Instructor guides the rotation of the scapula towards the spine until a soft contact is achieved.

Self-check during expansion: a) the Aero-Line does not touch the knuckles; b) after scapular rotation, the contact is soft.
Fig. AX.9 — Self-check during expansion: a) the Aero-Line does not touch the knuckles; b) after scapular rotation, the contact is soft.

Self-check after release (Exercise 13.1). The learner releases and holds the final position (static follow-through), focusing on the contact of the Aero-Line. If the green elastic stays away from the body, the release happened in collapse: back tension was lost through a missing or incomplete contraction of the rhomboids and lower trapezius. If the Aero-Line rests evenly at the base of the neck or on the torso, the scapulae have completed their rotation and retraction around the spine, maintaining the push-and-pull line.

Self-check after release: a) error, the Aero-Line stays away from the body; b) correct execution, the Aero-Line rests at the base of the nec
Fig. AX.10 — Self-check after release: a) error, the Aero-Line stays away from the body; b) correct execution, the Aero-Line rests at the base of the neck.

Safety. Check the integrity of the cords before every session; the tensioned cords work near the face and must be kept away from the eyes. Do not use the device if the red load cord or the Aero-Line show micro-cuts, fraying or surface damage. When adjusting the Tension Block and the Position Adjuster, never point the tensioned cords towards the face of the archer or anyone else. Under the age of 14, the AeroAxis™ is used only under the direct supervision of an Instructor or a responsible adult.

5.3Infinity FormLine™ — Stability of the Bow Shoulder and Bow Arm

What it is for. It works on raising the bow arm and on shoulder stability. The continuous downward pull asks the bow shoulder to activate its stabilisers (latissimus dorsi, lower trapezius, rotator cuff), so that it stays low, open and aligned.

How it is made. An attachment that fixes to the structure of the Infinity Bow™, a calibrated elastic tube and a sliding mechanism that lengthens or shortens the circuit in a few seconds. The system is ambidextrous and adapts to different body types.

Fitting. It is fixed to the structure with a single dedicated screw, which creates a rigid, stable connection. The other end of the tube hooks onto the archer’s foot. Resistance is adjusted with the sliding mechanism: long circuit for low resistance, short circuit for high resistance.

In the sequence. Pre-loaded raise (5): the tube counters the lift and teaches the archer to raise the tool without raising the shoulder. Exercise 5.2.

Safety. The tube works under tension: check its integrity before every session, paying particular attention to the attachment points on the structure and on the foot. Do not use it if there are micro-cuts, fraying or separation, and adjust it with the work area clear of other people.

5.4G.A.S.™ (Gap Alignment System) — Proprioception of the Bow Hand

What it is for. Every slightest tension or pressure of the bow hand affects the flight of the arrow. The G.A.S.™ makes these micro-variations visible to the archer and the Instructor before the release.

How it is made. A fork mount that fits onto the top of the frame and locks with a red knurled-knob pin; a longitudinal guide along the line of aim and push; a rear sight, close to the archer’s eye, with a vertical reference; a front sight, towards the target, with a horizontal reference; a cylindrical bubble level (29 × 9.5 mm) below the rear sight, on the archer’s side; a side band with the laser-engraved logo.

Fitting. It is fitted on the top of the Infinity Bow™ frame and locked by fully inserting the red pin. Red is a safety choice common to all the accessories’ locking pins: it lets you check at a glance that the pin is inserted.

How to read it. Neutral push without torque: looking through the rear sight, the two references form a centred cross. Pressure towards the web between thumb and index finger or towards the heel of the palm: the horizontal reference of the front sight rises or falls relative to the centre. Wrist collapsing or rotating: the vertical reference of the rear sight moves sideways. Sideways tilt of the tool (canting): the bubble moves off centre. The level is on the archer’s side because it gives an immediate reference on the position of the bow hand.

In the sequence. Bow grip (3), fine adjustments (6) and, in sighted shooting, sight alignment (15). Exercises 3.4, 6.1 and 15.1. The model views are in Plates 5.2 and 5.3.

Safety. It has no tensioned parts or elastic elements: no special procedures are needed beyond checking the locking pin.

5.5Clicker Simulator™ — Expansion and Click for the Olympic Recurve

What it is for. It simulates the clicker’s click at the end of the expansion and lets you train continuous expansion without releasing an arrow. It helps take the tension out of the archer’s relationship with the clicker.

How it is made. A body made of two PETG shells, closed by 4 M4×20 screws, with laser-engraved graphics on the front shell. Inside the body slides the plunger, which the archer pulls with the cord; a friction blade printed into the plunger gives constant resistance. After 20 mm of travel the magnetic head drops down a 60° ramp and four Ø8×3 mm neodymium magnets engage with a sharp click; a stop tooth halts the plunger at 24 mm. The plunger comes in three interchangeable versions: Light, Medium and Hard. To change it, remove the 4 screws and open the body.

Fitting accessories. A green L-shaped bow mount that wraps the grip of the Infinity Bow™ and is crossed by the locking pin with its red knurled knob; a draw-length adjuster, a black block with a lever cam, fitted on the cord near the plunger eyelet; a cord coupler, two small red TPU elements that connect the Clicker cord to the Infinity Bow™ cord.

Fitting. Rest the mount on the grip, with the Clicker facing the inside of the ring, and fully insert the red pin. Connect the cord to the Infinity Bow™ cord with the coupler and adjust its length with the draw-length adjuster: the click must come at the end of the expansion, not before the anchor. The red of the pins is a safety choice: it lets you check at a glance that the pin is inserted.

Resetting. Lift the magnetic head, separating the magnets, push the plunger all the way in and release the head. The starting position is always the same, so the travel is repeatable.

In the sequence. Expansion (11) and release (12) on the Olympic recurve. Start with the Light plunger and move gradually to Medium and Hard. Exercises 11.2 and 11.4. The model views are in Plates 5.4 and 5.5.

Safety. The cord works under tension: check its integrity and knots before every session. Check that the red pin is fully inserted and that the body screws are tight. The neodymium magnets are small and attract strongly: keep the module and spare parts out of the reach of children, away from pacemakers and from magnetic media. Do not point the device towards the face.

5.6I-Loop (Infinity Loop™) — Quick Release and the Compound Wall

What it is for. It has two functions. For compound archers, the end stop simulates the bow’s wall and lets them train drawing, holding and expanding against the wall. In schools, the quick release lets the same Infinity Bow™ pass from one learner to another: those who shoot compound work with the I-Loop, the others without.

Fitting. It clips around the 2 mm cord between the two elastics. Quick fitting is shown in Karman Training’s dedicated videos.

In the sequence. Expansion (11) on the compound. Exercises 11.3 and 11.4.

Safety. Before use, check that the I-Loop is correctly closed around the cord and that the cord is intact.

Plates

a) Three-quarter view in the position of usea) Three-quarter view in the position of use
b) Side view: band with the laser engravingb) Side view: band with the laser engraving
c) Detail of the bubble level (29 × 9.5 mm)c) Detail of the bubble level (29 × 9.5 mm)
Plate 5.2 — G.A.S.™: 3D model with laser engraving, bubble level on the archer’s side and red locking pin. Fig. 5.2a — Three-quarter view in position of use · Fig. 5.2b — Side view: band with laser engraving · Fig. 5.2c — Detail of the bubble level (29 × 9.5 mm)
a) Line of sight, archer sidea) Line of sight, archer side
b) Line of sight, target sideb) Line of sight, target side
c) Isometric, opposite sidec) Isometric, opposite side
d) View from below, attachment sided) View from below, attachment side
Plate 5.3 — G.A.S.™: views of the 3D model. Fig. 5.3a — Line of aim, archer’s side · Fig. 5.3b — Line of aim, target side · Fig. 5.3c — Isometric, opposite side · Fig. 5.3d — View from below, mounting side
Key to the views — G.A.S.™
ViewDescription
5.2a · Three-quarterThe G.A.S.™ in position of use, sights up: engraved band, level below the rear sight with the vertical reference, mounting fork with the red pin.
5.2b · SideThe band seen face-on, with the engraving; on the right, the level seen end-on.
5.3a · Aim, archer’s sideWhat the archer sees: the two sights overlap to form the centred cross; below the rear sight, the level, with the bubble between the marks, gives the reference on the position of the bow hand.
5.3b · Aim, target sideThe same line of sight from the target side, useful for the Instructor to observe the alignment of the sights.
5.3c · IsometricThe side without engraving: the fork, the red pin and the knurled knob that locks the G.A.S.™ onto the frame.
5.3d · From belowThe side that rests on the Infinity Bow™ frame: the ends of the fork and the pin that crosses them.
a) With accessories, three-quarter viewa) With accessories, three-quarter view
b) Mounted on the Infinity Bow™ gripb) Mounted on the Infinity Bow™ grip
Plate 5.4 — Clicker Simulator™ v2: 3D model with accessories, alone and fitted on the Infinity Bow™. Fig. 5.4a — With accessories, three-quarter view · Fig. 5.4b — Fitted on the grip of the Infinity Bow™

Visible components. Body with laser engraving; green magnetic head; plunger with eyelet; red locking pin; green L-shaped bow mount; cord with draw-length adjuster (black block with lever cam) and red TPU coupler to the Infinity Bow™ cord.

a) Front viewa) Front view
b) Rear viewb) Rear view
c) Top viewc) Top view
d) Mounted on the Infinity Bow™, front viewd) Mounted on the Infinity Bow™, front view
Plate 5.5 — Clicker Simulator™ v2: views of the 3D model. Fig. 5.5a — Front view · Fig. 5.5b — Rear view · Fig. 5.5c — Top view · Fig. 5.5d — Fitted on the Infinity Bow™, front view
Key to the views — Clicker Simulator™
ViewDescription
5.5a · FrontThe side with the “Clicker Simulator” engraving: on the right, the L-shaped mount and the red pin; on the left, the eyelet where the cord starts.
5.5b · RearThe rear shell and the mount, crossed by the pin.
5.5c · TopThe mount wrapping the grip, the magnetic head above the body and the cord in line with the plunger.
5.5d · FittedThe Clicker cord runs horizontally from the eyelet to the Infinity Bow™ cord, on the opposite side of the ring.